Beta — potential building sites, not active for-sale listings. Verify ownership & availability before acting on anything here.

Aerial view of 118 Deerwood Lane North, Plymouth with the parcel boundary outlinedAerial: MnGeo / USDA FSA (flown 2021) · boundary: county GIS

118 Deerwood Lane North, Plymouth

Parcel PIN 053-3511822440007 · Hennepin County · 55441

Ask about this lot

Potential build site — identified from county GIS · as of 7/21/2026

Lot size
0.9 acres
Buildable envelope
11,761 sq ftlimited by the coverage cap — details below
School district
Wayzata Public School District
Land type
Vacant land — residential
  • FEMA flood zone AE
  • Wetland indicators mapped
  • In the regional wastewater service area (MUSA)
  • Partially wooded — ~43.6% tree canopy (2015 modeled)

All site signals below are preliminary site signals — not a determination. Verify before you rely on them.

Data confidence

A plain-language status — not a score. This page documents 4 facts from public records (one of them the 5 building rules cited to Plymouth City Code §21360.13), estimates 2 more from models, relies on 2 unverified screening defaults, and lists 8 things to verify before you rely on it.

What we know
4 documented signals (building rules (cited), parcel boundary, jurisdiction, market status) — each carries its source and as-of date below.
What we estimate
2 modeled values (preliminary setback envelope (per-edge — front/rear/side from parcel geometry and street frontage), sewer proximity (estimated)) — modeled, not measured; treat as screening only.
What needs verification
8 items only a professional or the city can confirm — the full checklist is below.
Rules basis
Plymouth single-family residential (RSF-2, typical) — Plymouth City Code §21360.13 (Municode Supp. 8 Upd. 2, updated 2026-06-26; codified through Ord. 2026-05) + regional screening defaults for rules not yet loaded — City values shown are for the typical single-family district — per-parcel zoning is not ingested, so confirm your parcel’s specific zoning district with the city. Some rules shown use a regional screening default — the Plymouth ordinance is not yet loaded for them; verify locally before relying on any number.

Plain-English summary

This parcel in Plymouth sits in the Wayzata Public School District school district. Part of the parcel is mapped in a FEMA Special Flood Hazard Area, so flood insurance and elevation requirements likely apply. Wetland indicators overlap the parcel in screening data — a field delineation is the next step, since mapped lines are not legal boundaries. On utilities, water service is undocumented and sewer service is inside the regional service area — a connection is not confirmed until the city or utility confirms it, so budget time to verify location and fees. The lot is partially wooded in the 2015 modeled estimate — some tree cover to work with, some open ground. We do not yet have data on terrain and water service — on this page, unknown never means "no concern."

Rules applied: Plymouth single-family residential (RSF-2, typical) — Plymouth City Code §21360.13 (Municode Supp. 8 Upd. 2, updated 2026-06-26; codified through Ord. 2026-05) + regional screening defaults for rules not yet loaded City values shown are for the typical single-family district — per-parcel zoning is not ingested, so confirm your parcel’s specific zoning district with the city. Some rules shown use a regional screening default — the Plymouth ordinance is not yet loaded for them; verify locally before relying on any number.

What we know, what we estimate, what you must verify

What we know

Recorded, authoritative facts.

  • Building rules (cited)5 rule sets cited to Plymouth City Code §21360.13

    Source: Plymouth single-family residential (RSF-2, typical) — Plymouth City Code §21360.13 (Municode Supp. 8 Upd. 2, updated 2026-06-26; codified through Ord. 2026-05) · as of 6/26/2026 · 90% confidence

  • Parcel boundaryRecorded county GIS parcel on file (not a survey)

    Source: County GIS

  • JurisdictionPlymouth, Hennepin County

    Source: County GIS

  • Market statusPotential build site — identified from county GIS

    Source: MetroGIS Regional Parcel Dataset (MN Geospatial Commons) · as of 7/21/2026

What we estimate

Modeled or preliminary — useful for screening, not decisions.

  • Preliminary setback envelope (per-edge — front/rear/side from parcel geometry and street frontage)After each edge's own required setback — front to the street edge, rear opposite, sides to the side lines — roughly 11,761 sq ft remains buildable — preliminary, not an approval or survey. The binding limit here is the 30% structural coverage cap (§21360.13): ≈ 11,761 sq ft - smaller than the 27,555 sq ft the setbacks alone would allow. Based on Plymouth single-family residential (RSF-2, typical) — Plymouth City Code §21360.13 (Municode Supp. 8 Upd. 2, updated 2026-06-26; codified through Ord. 2026-05); confirm your parcel's zoning. Base front setback applies — this lot fronts Deerwood Lane North (Local Road, Met Council functional class), not an arterial street.

    Source: Plymouth single-family residential (RSF-2, typical) — Plymouth City Code §21360.13 (Municode Supp. 8 Upd. 2, updated 2026-06-26; codified through Ord. 2026-05) · as of 6/26/2026 · 55% confidence

  • Sewer proximity (estimated)Public utilities may be available nearby; connection location & fees require confirmation

    55% confidence

What you must verify

Professional and municipal confirmations before you build.

  • Boundary survey (a recorded GIS boundary is not a survey)
  • Wetland delineation by a certified delineator
  • Soil borings & septic feasibility (if no municipal sewer)
  • Utility connection points, capacity and SAC/WAC fees with the city or utility
  • Permit eligibility and any overlay/PUD conditions with the jurisdiction
  • Easements, covenants and title work
  • Final setbacks and buildable area per the current local ordinance
  • Actual construction cost from builder quotes

What each signal means

Written for homeowners; open “the details” on any card for the builder view and the raw measurement behind it.

Slope & terrain

Unknown

Slope & terrain: not yet evaluated — unknown is not the same as no concern. no slope statistics

The details

Builder view: Slope & terrain: no qualifying evidence in the current dataset (no slope statistics); treat as unresolved, not as clear.

No underlying measurement on file for this signal.

  • Unknown ≠ clear: absence of data is never treated as "no concern".

0% confidence

Flood mapping

Concern

Part of this parcel is mapped in a FEMA Special Flood Hazard Area (zone AE); flood insurance and elevation requirements likely apply — confirm with the city and a surveyor.

The details

Builder view: FEMA zone AE (SFHA) per current NFHL data; floodplain ordinance and base flood elevation requirements apply — elevation certificate and local floodplain review required.

  • FEMA flood zone: Zone AE (FEMA special flood hazard area)

    Source: FEMA NFHL flood hazard zones (MN DNR GDRS mirror) · as of 7/21/2026 · 90% confidence

  • Zone boundary is map-scale; a surveyed elevation governs.

90% confidence · source: FEMA NFHL flood hazard zones (MN DNR GDRS mirror) · as of 7/21/2026

Wetland indicators

Concern

Mapped wetland/public-water indicators overlap this parcel. This is a screening result, not a confirmed legal boundary — a wetland delineation is recommended before design or purchase decisions.

The details

Builder view: NWI/PWI overlap present — a SCREENING constraint, not a delineated boundary; a wetland delineation is recommended before design or purchase decisions. The local ordinance requires a vegetated buffer of 20–67 ft depending on the wetland's classification, plus a structure setback from the buffer (Plymouth requires a vegetated buffer of 20 to 67 feet depending on the wetland’s quality classification, plus a 15-foot structure setback from the buffer edge — roughly 35 to 82 feet from the wetland itself (Plymouth City Code §21670.05). A delineation and MnRAM classification set the exact figure, and Plymouth’s code states these setbacks take precedence over the district’s ordinary setbacks.) — a delineation and classification set the exact figure. WCA/LGU review applies if impacts are proposed.

  • Wetland mapped (NWI): Yes

    Source: Updated MN National Wetlands Inventory · as of 7/21/2026 · 90% confidence

  • DNR public waters: Yes

    Source: DNR Public Waters Inventory basins · as of 7/21/2026 · 90% confidence

  • Screening-level mapping only; field conditions govern.

90% confidence · rule tier: local (city/township) ordinance data · source: Updated MN National Wetlands Inventory; DNR Public Waters Inventory basins · as of 7/21/2026

Sanitary sewer

Info Modeled

Public utilities may be available nearby; connection location & fees require confirmation

Uses a regional screening default — the local ordinance is not yet loaded. Verify locally.

The details

Builder view: sanitary sewer: inside the regional wastewater service area (MUSA) — membership is a planning designation, NOT a connection at the boundary; timing unknown, confirm staging with the city.

  • Sewer service state: Inside planned regional wastewater service area — not a sewer connection
  • Service-area membership is modeled from regional GIS, not utility records.
  • Without a municipal sewer connection, an on-site septic system (SSTS) is required, including a primary and alternate drainfield site (regional/state screening default (unverified) — not the local ordinance; verify with the jurisdiction).

55% confidence · rule tier: regional screening default (unverified)

Water service

Unknown

Water service: not yet evaluated — unknown is not the same as no concern. water service not documented

The details

Builder view: Water service: no qualifying evidence in the current dataset (water service not documented); treat as unresolved, not as clear.

No underlying measurement on file for this signal.

  • Unknown ≠ clear: absence of data is never treated as "no concern".

0% confidence

School district

Info

This parcel is in the Wayzata Public School District school district per current boundary data.

The details

Builder view: School district: Wayzata Public School District (MDE boundary data; boundaries can change — verify for enrollment decisions).

  • School district: Wayzata Public School District

    Source: MDE school district boundaries · as of 7/21/2026 · 90% confidence

90% confidence · source: MDE school district boundaries · as of 7/21/2026

Setback & frontage envelope

Info

After each edge's own required setback — front to the street edge, rear opposite, sides to the side lines — roughly 11,761 sq ft remains buildable — preliminary, not an approval or survey. The binding limit here is the 30% structural coverage cap (§21360.13): ≈ 11,761 sq ft - smaller than the 27,555 sq ft the setbacks alone would allow. Based on Plymouth single-family residential (RSF-2, typical) — Plymouth City Code §21360.13 (Municode Supp. 8 Upd. 2, updated 2026-06-26; codified through Ord. 2026-05); confirm your parcel's zoning. Base front setback applies — this lot fronts Deerwood Lane North (Local Road, Met Council functional class), not an arterial street.

The details

Builder view: Setbacks applied per edge (front/rear/side identified from parcel geometry and street frontage): envelope ≈ 27,555 sq ft (front 25 ft, side 10 ft, rear 25 ft, corner side 25 ft; 100% of the boundary classified); coverage cap governs at ≈ 11,761 sq ft; preliminary planar computation — not an approval or survey. The binding limit here is the 30% structural coverage cap (§21360.13): ≈ 11,761 sq ft - smaller than the 27,555 sq ft the setbacks alone would allow. Based on Plymouth single-family residential (RSF-2, typical) — Plymouth City Code §21360.13 (Municode Supp. 8 Upd. 2, updated 2026-06-26; codified through Ord. 2026-05); confirm your parcel's zoning. Base front setback applies — this lot fronts Deerwood Lane North (Local Road, Met Council functional class), not an arterial street.

No underlying measurement on file for this signal.

  • Preliminary — not an approval or survey.
  • Edge roles identified from parcel geometry and street frontage (100% of the boundary classified) — verify with a survey.
  • Confidence is limited by: the zoning district is assumed (the city’s typical single-family district), not verified for this parcel.

55% confidence · rule tier: local (city/township) ordinance data · source: Plymouth single-family residential (RSF-2, typical) — Plymouth City Code §21360.13 (Municode Supp. 8 Upd. 2, updated 2026-06-26; codified through Ord. 2026-05) · as of 6/26/2026

Shoreland status

N/A

This lot is outside mapped shoreland zones — no public water within 1,000 ft (lake) or 300 ft (watercourse) in the current DNR screening.

The details

Builder view: Not in a DNR PWI shoreland zone per statutory-distance screening; shoreland overlay standards do not apply. Screening-level: the mapped OHWL is not a survey.

  • DNR shoreland classification: Not in a shoreland district

    Source: DNR Public Waters Inventory basins · as of 7/25/2026 · 90% confidence

  • No mapped public water within 1000 ft (lake) / 300 ft (watercourse) of this parcel in the current DNR PWI screening.

90% confidence · source: DNR Public Waters Inventory basins · as of 7/25/2026

Trees & canopy

Info Modeled

This lot is partially wooded — about 43.6% tree canopy (2015 modeled estimate): some tree cover, some open ground.

The details

Builder view: Tree canopy ≈ 43.6% of parcel area (Partially wooded; bands: wooded ≥ 50%, partially wooded 20–50%). Source: 2015 UMN 1-m urban tree canopy (deciduous + coniferous classes); verify current conditions on site — clearing, storms and growth since 2015 are not reflected.

  • Tree canopy coverage (%): 43.6%

    Source: UMN 2015 TCMA Urban Tree Canopy (1 m, RSGAL/DRUM) · as of 7/25/2026 · 75% confidence

  • Modeled from the 2015 UMN 1-m urban tree canopy raster; canopy may have changed since 2015. Screening only, not a survey.
  • Modeled from the 2015 UMN 1-m urban tree canopy raster (deciduous + coniferous classes); canopy may have changed since 2015. Screening only, not a survey.

60% confidence · source: UMN 2015 TCMA Urban Tree Canopy (1 m, RSGAL/DRUM) · as of 7/25/2026

Build on this lot

A builder can turn the verify list above into answers — ask about this lot with no obligation.

Get a build evaluation from vetted Twin Cities builders. This is a request to find a builder — not a real-estate listing or offer of representation.

Build in Plymouth

These builders list Plymouth in their service area (HomeBuildersMN directory, as of 2026-07-25).

Site signals

The raw per-field record behind the interpretation above — the same rights-filtered fields, each with its own source and last-verified date.

School district Info Verified

Wayzata Public School District

Source & last verified

Source: MDE school district boundaries. Last verified: 7/21/2026.

Flood zone Concern Verified

Zone AE (FEMA special flood hazard area) Preliminary site signal — not a determination.

Source & last verified

Source: FEMA NFHL flood hazard zones (MN DNR GDRS mirror). Last verified: 7/21/2026.

Wetland presence Concern Verified

Yes NWI is a planning tool; preliminary, not a delineation.

Source & last verified

Source: Updated MN National Wetlands Inventory. Last verified: 7/21/2026.

DNR public waters Concern Verified

Yes

Source & last verified

Source: DNR Public Waters Inventory basins. Last verified: 7/21/2026.

DNR shoreland classification N/A Verified

Not in a shoreland district No mapped public water within 1000 ft (lake) / 300 ft (watercourse) of this parcel in the current DNR PWI screening.

Source & last verified

Source: DNR Public Waters Inventory basins. Last verified: 7/25/2026.

Tree canopy coverage (%) Info Modeled

43.6% Modeled from the 2015 UMN 1-m urban tree canopy raster (deciduous + coniferous classes); canopy may have changed since 2015. Screening only, not a survey.

Source & last verified

Source: UMN 2015 TCMA Urban Tree Canopy (1 m, RSGAL/DRUM). Last verified: 7/25/2026.

Site sewer Service Class Info Verified

sewered Inside the Met Council Current Wastewater Service Areas footprint — currently served, not merely planned.

Source & last verified

Source: Met Council Current Wastewater Service Areas (LPH publication). Last verified: 8/4/2026.

Utilities

Sewer Info Modeled

Inside planned regional wastewater service area — not a sewer connection

Nearby sites in Plymouth